Coagulation Tube (3.2% Sodium Citrate, 1:9 Ratio)
Designed for coagulation tests including: Prothrombin Time (PT), Thrombin Time (TT), Activated Partial Thromboplastin Time (APTT), and Fibrinogen assays. Features precise 1:9 anticoagulant-to-blood ratio to ensure diagnostic accuracy and prevent misdiagnosis. The low-toxicity sodium citrate formulation also enables blood preservation. Double-sleeve tubes eliminate dead space, making them ideal for:
– Hemophilia factor/VIII factor testing
– Platelet function analysis
– Heparin therapy monitoring
Description
Specifications
| Catalog No. | Tube Size | Tube Material | Nominal Volume | Additive | Tubes/Tray | Tubes/Case | Remarks | Product Code |
|---|---|---|---|---|---|---|---|---|
| KJ018NC | Ø13×75mm | Glass | 2ml | 3.2% Sodium Citrate | 100 | 1800 | Gently invert 6-8 times immediately after collection, then centrifuge. | 0109-0211 |
| – | Ø13×75mm | PET | 2ml | 3.2% Sodium Citrate | 100 | 1800 | – | 0109-0212 |
| KJ027NC | Ø13×75mm | Glass | 3ml | 3.2% Sodium Citrate | 100 | 1800 | – | 0109-0311 |
| – | Ø13×75mm | PET | 3ml | 3.2% Sodium Citrate | 100 | 1800 | – | 0109-0312 |
| KJ036NC | Ø13×75mm | Glass | 4ml | 3.2% Sodium Citrate | 100 | 1800 | – | 0109-0411 |
| – | Ø13×75mm | PET | 4ml | 3.2% Sodium Citrate | 100 | 1800 | – | 0109-0412 |
| KJ018NC | Ø13×75mm (Double-Sleeve) |
PET | 2ml | 3.2% Sodium Citrate | 100 | 1800 | – | 0109-0212D |
| KJ027NC | Ø13×75mm (Double-Sleeve) |
PET | 3ml | 3.2% Sodium Citrate | 100 | 1800 | – | 0109-0312D |
Product Overview
Designed for coagulation tests including: Prothrombin Time (PT), Thrombin Time (TT), Activated Partial Thromboplastin Time (APTT), and Fibrinogen assays. Features precise 1:9 anticoagulant-to-blood ratio to ensure diagnostic accuracy and prevent misdiagnosis. The low-toxicity sodium citrate formulation also enables blood preservation. Double-sleeve tubes eliminate dead space, making them ideal for:
– Hemophilia factor/VIII factor testing
– Platelet function analysis
– Heparin therapy monitoring
Key Features
① Safety Cap
- Premium butyl rubber stoppers optimized for automated analyzers with excellent airtightness, minimal coring (≤0.1μg debris), and needle rebound prevention
- Specialized compound reduces needle wear, doubling needle lifespan versus standard stoppers
- Patented locking mechanism prevents cap dislodgement during handling
- Universal compatibility with decapping equipment
- Color-coding compliant with CLSI standards
② Premium Tube Material
- Medical-grade PET with superior chemical stability
- Silicone-coated interior (≤0.5μm surface roughness) prevents cell adhesion
- Biomimetic inner surface preserves platelet morphology
③ Custom Labeling
- Barcode-ready labeling solutions with scratch-resistant printing (≥1,000 scan cycles durability)
- Tear-off labels for aliquot identification
- Pre-applied labels meeting GMP traceability requirements




